Bio Technics India manufactures laboratory equipment for centrifugation heating and incubation applications used across research and diagnostic laboratories.We provide these solutions to ensure dependable performance and precision driven results.
OIL BATH
(HSN CODE: 84191920) S. S. 316 construction, s. s. 316 heater, bakelite handles, single walled (no insulation), suitable for heating round bottom glass flasks to a maximum temperature of 250o C .with Digital Temp.Controller.
OIL BATH (ROUND)
Consruction-Double walled outer body made of M.S powder coatied& inner body made of S.S body
MUFFLE FURNACE ( 1130C) with Digital Temp Controlled
(HSN CODE: 85141000) Construction: Outer Body made of Mild Steel powder coated. Inner Body made of ceramic Muffle Kumar make. Insulation: Special type ceramic Insulation between body for Insulation. Coil: Kanthal A1 swaden make coil for long lasting. Temp Range: 400 C to max 1150C. Accuracy: +/- 3 deg.
MUFFLE FURNACE (GMP MODEL)
(HSN CODE: 85141000) Specification:Construction: Outer Body made of Stainless Steel. Inner Body made of ceramic Muffle Kumar make. Insulation: Special type ceramic Insulation between bodies for Insulation. Coil: Kanthal A1 swaden make coil for long lasting. Temp Range: 400 C to max 1150C. Accuracy: +/- 3 deg.
MELTING POINT APPARATUS
(HSN CODE: 85141000) It is useful for the determination of melting point of any substance upto 300C. It consists with aluminum cylindrical block for heating and radial holds a thermometer and glass capillary.
MAGNETIC STIRRER WITH HOT PLATE
(HSN CODE: 84798200) S. S. Top Plate & Body M.S. powder coated with speed regulator & temp Regulator. Max surface Temp: 120 deg. Max RPM: 1000
LEAK TEST APPARATUS
(HSN CODE: 90278090) Working Chamber : Polycarbonate Desiccators Outer Chamber : Stainless Steel Digital Timer : 99 Minutes Vacuum Pump : Oil less vacuum pump (diaphragm Type) Provided with dial type vacuum gauge & vacuum release valve
LAMINAR AIR FLOW CABINETS
(HSN CODE: 84192090) Laminar Flow Cabinets complete with HEPS filter having efficiency of 99.97%down on 0.3%microns.pre filter 90 % down to 5 micron, suitable motor blowing assemblies, working table SS top, side Acrylic panel, fluorescent tube Lights & Pressure differential manometer & castor wheels. U. V. Light & Gas cork & Plexi doors.
LABORATORY OVEN (Memmert Type)
(HSN CODE: 85141000) Construction: Tripled walled outer body made of Mild Steel powder coated & Inner Body of 2 chambers made of Stainless Steel 304. Insulation: Glass wool Insulation between two walled Temp range: 10 C above room temp to 250C. Temp Accuracy: +/- 1Deg. Temp Controlled by: Microprocessor PID controller with dual display & auto tune facility. Air circulation By: In this model we give Air circulation motor with blower for uniform temp inside chamber.
LABORATORY OVEN (Lab Type)
(HSN CODE: 85141000) Construction: Double walled construction outer body made of Mild Steel powder coated, & Inner Body made of Stainless Steel grade S.S 304. Insulation: Glass wool insulation between two walled. Temp range: 50 C to 250C. Accuracy: +/- 2 C. Temp controlled by: thermostatic With G.I. wire Mesh selves
INCUBATOR BACTERIOLOGICAL (Memmert Type)
(HSN CODE: 84191920) (PRECISION INCUBATOR) Construction: Tripled walled outer body made of Mild Steel powder coated & Inner Body of 2 chambers made of Stainless Steel 304. Insulation: Glass wool Insulation between two walled Temp range: 5C above room Temp to 60C. Temp Accuracy: +/- 0.5 C. Temp Controlled by: Microprocessor PID controller with dual display & auto tune facility. Air circulation By: In this model we give Air circulation motor with blower for uniform temp inside chamber.
INCUBATORS BACTERIOLOGICAL (Lab Type)
(HSN CODE: 84191920) Construction: Double walled construction outer body made of Mild Steel powder coated, & Inner Body made of Stainless Steel grade S.S 304. Insulation: Glass wool insulation between two walled . Temp range: 5 C above room temperature to 60C. Accuracy: +/- 2 C. Temp controlled by: thermostatic With G.I. wire Mesh selves
STABILITY CHAMBER (GMP MODEL)
(HSN CODE: 84198990) Double Walled construction Outer S.S.304 & Inner S.S.316 PUF Insulation between Two Walled Temp. Range 10 C to 60 C with Accuracy 1C Humidity Range: 35% to 98% RH3% RH Positive Vertical Circulation by Motorized Blower for Uniform Temp. Temp. Controlled By PID Controller
HUMIDITY CONTROL OVEN (Cooling)
(HSN CODE: 84198990) Also know as Environmental Test chamber or Stability chamber-Double Walled Inner SS-Outer MS-3Gap Glass Wool insulation: Full length inner acrylic door for clear inner view-outer metal door with magnetic gaskets & lock. Forced air circulation for uniform temperature throughout the chamber. Digital display preset electronic digital temperature controller cum indicator but with cooling system by means of hermetically sealed Compressor Unit coupled with evaporation Coil and condenser. Temp. Range 10C to 60C 1C: Humidity Range 40% RH to 85% RH 3% RH
HOT PLATE RECTANGULAR
(HSN CODE: 84191920) Maximum surface temperature 350C, with C .I. Top & M.S.Body
HOT PLATE ROUND (LABORATORY TYPE)
(HSN CODE: 84191920) Top made of cast iron and body of mild steel powder coated. Max surface temp 350 C.
HOT AIR OVEN (GMP MODEL)
(HSN CODE: 85141000) Double walled construction fully made of Stainless steel Inner S.S.316 & Outer 304. The gap between the two walls filled with glass wool insulation. Temperature controlled by microprocessor based digital temp. Controller with PT100 as sensor & safety thermostat. Supplied with s. s wire mesh shelves and silicon gasket on door .with Air circulation fan Temp. Range: 50 C to 250 C accuracy +/-1 C.
HOT AIR OVEN (400C)
(HSN CODE: 85141000) Triple walled in construction inner chamber made of st. steel and exterior made of M.S. sheets powder coated. The gap between the two walls filled with glass wool insulation of 4.heating elements fitted on the two sides of the oven. A forced air circulating system with fan for better uniformity of temperature .Temperature controlled by electronics digital temperature controller.Temp.Range:50 C to 400 C .Accuracy 2C
HEATING MANTLES
(HSN CODE: 84191920) Aluminum housing with powder coating available in different sizes. Temp. Controller by energy regulator. Provided with high quality insulation.Max. surface Temp.300 C
FRIABILITY TEST APPARTUS (DIGITAL )
(HSN CODE: 90248099) Digital Timer preset counter Upto 99.9 minutes,25 revolution per 1 min universal acrylic drum for right or left side easy loading & unloading of the drum provide with drum.
FRIABILITY TEST APPARTUS (Non Digital)
(HSN CODE: 90248099) Mechanical timer for 5 Minutes.25 revolutions per 1 Min .universal acrylic drum for right or left side easy loading & unloading of drum. Provide with drum
FLOCULATOR JAR TEST APPARATUS
(HSN CODE: 90318000) Variable speed 50-100 RPM electric motor with gear chain for uniform speed in all multiple spindle stirrer and fluorescent tube for 1 Ltr beaker supplied without glass parts.
Request Details